Eib Knx Cable
Your Professional Eib Knx Cable Supplier
Chat Now is a manufacturing company focused on customized low-voltage communication cables and cable solution services. Our main products include SWA/SWB armored cables, RS485 cables, PROFIBUS cables, and SMPTE hybrid optical-electrical cables. These products are widely used in industrial automation, broadcasting, communication systems, and engineering projects.
Custom OEM Support
We provide OEM services for cable structure, materials, packaging, and small design adjustments based on customer requirements and project needs.
Professional Engineering Team
Our engineers offer practical support for cable selection, specifications, and application solutions to help customers improve project efficiency.
Stable Quality Control
With advanced production equipment and strict inspection processes, we ensure consistent cable quality, reliable performance, and stable delivery times.
Responsive Service
We provide fast communication, technical assistance, and long-term support to build smooth and reliable cooperation with global partners.
Your Professional Eib Knx Cable Supplier
|
Test items |
Performance index |
|
Conductor DC resistance |
≤37.7 Ω ·mm2/m(at 20℃) |
|
Insulation Resistance |
≥200MΩ.km |
|
Working temperature |
-25~+75℃ |
|
Working voltage |
300/300V |
|
Flame retardant requirement |
IEC60332-1-2 |
|
Smoke |
EN61034-4 |
|
Acidity |
EN 60754-1 &2 |
|
Environmental performance |
RoHS compliant |
Robust Construction
Made from high-quality materials, EIB/KNX cables are resistant to environmental factors such as moisture, chemicals, and temperature fluctuations.
Twisted Pair Design
EIB/KNX cables utilize twisted pair technology, which helps minimize electromagnetic interference and enhances signal integrity over long distances.
Flexible Installation
These cables can be easily routed in various building environments, making them ideal for new constructions and retrofitting existing systems.
Low Voltage Operation
Typically operates at low voltage levels, enhancing safety and reducing the risk of electrical shock.
Versatile Applications
Suitable for a wide range of building automation tasks, including lighting, heating, ventilation, air conditioning, and security systems.
High Transmission Speed
Designed to support high data transmission rates, enabling fast communication between devices and systems.
Compatibility With KNX Standard
Fully compliant with the KNX standard, ensuring interoperability between devices from different manufacturers.
Intelligent buildings control
Lighting: Centralized ignition command, Intensity variation and smart lighting scenarios (ex. : Automatic brightness adjustment to save energy).
HVAC (heating, ventilation, air conditioning): Liaison with temperature and humidity sensors for intelligent interior comfort piloting.
Energy security and management
Integration of access control systems, cameras, Fire alarms, with real -time reaction to abnormal events.
Energy consumption monitoring and optimization of electricity distribution (ex. : Automatic extinction of non -essential equipment).
Industrial automation
Reliable transmission between automata, Sensors and actuators in the industrial environment, To improve the efficiency of production lines.
Residential home automation
Intelligent blinds of blinds, air conditioners, Safety devices, To create a comfortable life experience, Connected and efficient.

Installation Considerations for Eib Knx Cable
Cable Routing
Always route cables away from sources of interference such as high-voltage cables, electrical panels, and large motors. This helps to maintain signal integrity and reduces the risk of communication errors. Use cable trays, conduits, or ducts to keep cables organized, especially in larger installations, and ensure that cables are adequately protected from mechanical damage.
Minimum Bend Radius
Avoid sharp bends or tight loops in the cables, as this can cause signal degradation or damage the internal wires. Always follow the minimum bend radius specified by the cable manufacturer.
Separation from High Voltage Cables
Keep KNX cables at least 10-20 cm away from high-voltage cables (e.g., 230V AC circuits). This prevents electromagnetic interference (EMI) and ensures stable data transmission.
Grounding and Shielding
Proper grounding and shielding are essential in installations with high electromagnetic interference (EMI). Make sure to use shielded cables (STP) in environments with significant electrical noise to maintain the integrity of the communication signals.
Cable Length and Device Count
When planning the layout of the system, ensure that the cable length does not exceed the maximum recommended distance . Maximum cable length (typically 1000 meters for TP). Use repeaters or couplers if longer distances or more devices are required.
Ordering Process
Inquiry - Quotation - Communication - Order Confirming - Deposit Payment - Production - Testing And Debugging - Balance Payment - Packing - Delivery - Customer Receiving - After Service.
Packaging and Shipping
|
Packaging |
Coil or Drum packaging Packing length can be adjusted based on installation needs. |
|
Shipping |
Shipping by sea, by air, by express are acceptable. According to your requirements. |
Our Certificates




FAQ
Zhejiang Chatnow New Material Technology Co., Ltd. is well-known as one of the leading eib knx cable manufacturers and suppliers in China, specialized in providing high quality customized service. Please feel free to wholesale high-grade eib knx cable at competitive price from our factory.
bus cable, EIB KNX BUS Cable Green, eib knx cable







