Shielded CAN Bus Communication Cable 2PR×0.25mm²

Shielded CAN Bus Communication Cable 2PR×0.25mm²

The Shielded CAN Bus Communication Cable 2PR×0.25mm² is engineered for reliable data transmission in CAN (Controller Area Network) systems used across industrial automation, transportation, energy, and intelligent equipment. Featuring two twisted pairs of finely stranded copper conductors, high-coverage tinned copper braid shielding, and a durable PVC outer jacket, this cable delivers excellent electromagnetic interference (EMI) protection, signal integrity, and long-term mechanical reliability.
Send Inquiry
Description
Technical Parameters

Zhejiang Chatnow New Material Technology Co., Ltd. is one of the leading manufacturers and suppliers of shielded can bus communication cable 2pr×0.25mm² in China. With abundant experience, we warmly welcome you to wholesale bulk high quality products at competitive price from our factory. We also accept customized orders.

 

 

APPLICATION

Designed for stable communication in electrically noisy environments, it is suitable for industrial control systems, machinery, robotics, and distributed automation networks.

The cable is ideal for high-reliability CAN communication networks, including:

  • Industrial automation and PLC communication
  • Factory automation equipment
  • Robotics and motion control
  • Intelligent manufacturing systems
  • Automotive testing equipment
  • Battery management systems (BMS)
  • Renewable energy monitoring systems
  • Marine electronic control systems
  • Distributed I/O and sensor networks

 

REGULAR PACKING

100M, 300M, 500M, 1000M, 500FT, 1000FT, Coil/Drum

 

Structural Design & Signal Benefits

Finely Stranded Copper Conductors

  • High-conductivity stranded copper provides excellent flexibility.
  • Low conductor resistance minimizes transmission loss.
  • Suitable for repeated movement and industrial installations.

Color-Coded PVC Insulation

  • Simplifies conductor identification during installation.
  • Ensures consistent dielectric performance.
  • Good electrical insulation and durability.

Twisted Pair Construction

  • Minimizes crosstalk between signal pairs.
  • Improves differential signal transmission.
  • Maintains stable communication over extended distances.

PP Fillers

  • Preserve the cable's round profile.
  • Increase mechanical stability.
  • Reduce deformation during installation.

PET Tape Wrapping

  • Maintains structural integrity.
  • Provides additional separation between the core and shielding.
  • Improves cable durability.

Tinned Copper Braided Shield

  • High shielding coverage effectively suppresses EMI/RFI.
  • Enhances communication reliability in industrial environments.
  • Reduces signal distortion and external electrical noise.

PVC Outer Jacket

  • Resistant to abrasion and mechanical wear.
  • Flexible for easy routing.
  • Good resistance to oils and common industrial contaminants.
  • Suitable for indoor industrial applications.

 

Installation & Performance Considerations

  • Observe the recommended minimum bending radius during installation.
  • Keep cable runs separated from high-voltage power cables whenever possible.
  • Properly ground the shield according to system design to maximize EMI protection.
  • Avoid excessive pulling force during installation.
  • Suitable for fixed industrial installations and general-purpose automation environments.

 

FAQ

Q1: What communication protocols is this cable suitable for?

A: It is designed primarily for CAN Bus communication and is suitable for CANopen, industrial CAN networks, BMS systems, robotics, automation equipment, and similar differential communication applications.

Q2: Why does the cable use braided shielding?

A: The high-coverage tinned copper braid significantly reduces electromagnetic interference (EMI), ensuring stable and reliable data transmission even in electrically noisy industrial environments.

Q3: Can the cable be customized?

A: Yes. Chatnow Cable provides OEM and ODM customization, including:

  • Conductor size
  • Number of pairs
  • Shielding type
  • Jacket material (PVC, PUR, LSZH, TPU)
  • Jacket color
  • Printing
  • Packaging
  • Length
  • Customer-specific construction

Q4: Is this cable suitable for outdoor installation?

A: The standard PVC version is intended for indoor industrial environments. For outdoor or harsh conditions, UV-resistant, LSZH, or PUR jacket options are available upon request.

Q4: Is this cable suitable for outdoor installation?

A: The standard PVC version is intended for indoor industrial environments. For outdoor or harsh conditions, UV-resistant, LSZH, or PUR jacket options are available upon request.

Q6: Can this cable be manufactured according to customer specifications?

A: Absolutely. Chatnow Cable specializes in custom industrial communication cables and can manufacture products according to customer drawings, technical specifications, or application requirements.

 

ABOUT COMPANY

07
08
09
9
8
7
6
5
4
1

 

CERTIFICATIONS

CERTIFICATIONS 1
CERTIFICATIONS 1
CERTIFICATIONS 2
CERTIFICATIONS 2
CERTIFICATIONS 3
CERTIFICATIONS 4
E540176-Fire Resistant Cable COC
 

 

MANUFACTURING PROCESS

MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
 

 

QUALITY INSPECTION

12
13
14
15
16
17
18
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Tags: shielded can bus communication cable 2pr×0.25mm², China shielded can bus communication cable 2pr×0.25mm² manufacturers, suppliers, factory, Automotive Can-Bus Cable, Can Bus Cable 2Prx0.75mm2, Can Bus RS485 Cable, CANBUS 1 2 0 5mm2, canbus cable, CanBus Data Cable

CONSTRUCTION

Conductor Material

Stranded Bare Copper

Conductor Surface / Structure

19/0.13 ± 0.005 mm

Core Insulation Material

Foam PE

Screen1 Material

PET Tape

Drain Material

N/A

Screen2 Material

Tinned Copper Braid

Material Outer Sheath

LSZH

 

CHARACTERISTICS

Cable performance(at 20℃)

Data of product

Inner Conductor DC Resistance

≤79.0Ω/km

Voltage test

AC 1kV/min

Operating voltage

250V

Impedance

120±15Ω

Capacitance conductor to conductor

Nom.36pF/m

Operation Temperature

-40~+70℃

Attenuation

1MHz: ≤1.5dB/100m
5MHz: ≤4.3dB/100m;
10MHz: ≤8.1dB/100m
20MHz: ≤10.5dB/100m

Flame Retardant

GB/T 18380.12-2008

UV

GB/T 29631-2013

Salt spray test

GB/T 29631-2013

Ozone resistance

GB/T2951.21