CHATNOW BS 6387 CWZ 3C×6mm² Fire-resistant Cable is designed to maintain circuit integrity during fire conditions while providing excellent mechanical protection and low-smoke, halogen-free performance. Constructed with stranded bare copper conductors, double mica tape fire barriers, XLPE insulation, LSZH inner and outer sheaths, and galvanized steel wire armour (SWA), this cable complies with BS 6387 CWZ requirements and is suitable for emergency power and life safety systems.
Rated voltage: 0.6/1kV
Operating temperature: -20°C to +90°C
Fire resistance: BS 6387 CWZ
Flame retardant standard: IEC 60332-1-2
Environmental compliance: RoHS 2.0
Send Inquiry
Description
Technical Parameters

Zhejiang Chatnow New Material Technology Co., Ltd. is one of the leading manufacturers and suppliers of fire-resistant cable bs 6387 cwz 3c×6mm2 in China. With abundant experience, we warmly welcome you to wholesale bulk high quality products at competitive price from our factory. We also accept customized orders.

 

 

APPLICATION

BS 6387 CWZ Fire-resistant Cable is intended for critical power circuits where continuous operation is required during

fire emergencies.

Typical applications include:

  • Fire alarm and emergency lighting systems
  • Smoke extraction and ventilation equipment
  • Fire pumps and sprinkler systems
  • Power supply for evacuation systems
  • Public buildings, hospitals, airports and tunnels
  • Data centers and industrial facilities
  • High-rise buildings and transportation infrastructure
  • Emergency backup power circuits

Its steel wire armour construction also provides additional mechanical protection for direct burial and outdoor installations.

 

REGULAR PACKING

100M, 300M, 500M, 1000M, 500FT, 1000FT, Coil/Drum

Customized Length: Available

Drum Marking: Customer Logo Available

Packaging: Export Seaworthy Wooden Drum

 

Structural Design & Signal Benefits

Layer Material Function
Conductor Stranded Bare Copper (19×0.63mm) Excellent conductivity and flexibility
Fire Barrier Double Mica Tape Maintains circuit integrity during fire
Insulation XLPE High dielectric strength and thermal stability
Filler Non-hygroscopic filler Ensures cable roundness
Binding Tape LSZH Tape Improves structural stability
Inner Sheath LSZH Low smoke and halogen-free protection
Armour Galvanized Steel Wire Armour Superior mechanical protection
Outer Sheath Flame-retardant LSZH Flame resistance and low smoke emission

 

Key Benefits

Excellent Fire Survival Capability

Double mica tape and BS 6387 CWZ design enable the cable to continue transmitting power under fire conditions, ensuring

operation of life safety systems.

Low Smoke Zero Halogen (LSZH)

Produces minimal smoke and no corrosive halogen gases, reducing hazards and protecting equipment during emergencies.

High Mechanical Strength

Steel wire armour provides outstanding resistance against impact, compression, and external mechanical damage.

Stable Electrical Performance

Conductor resistance ≤3.08 Ω/km

Dielectric strength: 3500V/5min without breakdown

Rated voltage: 0.6/1kV

Wide Temperature Range

Suitable for environments from -20°C to +90°C.

 

Installation & Performance Considerations

Recommended Installation

✔ Indoor and outdoor installation

✔ Cable tray and conduit systems

✔ Underground installation with suitable protection

✔ Industrial and commercial power distribution systems

✔ Emergency circuits requiring fire survival capability

Installation Guidelines

  • Avoid exceeding the minimum bending radius during installation.
  • Prevent excessive pulling tension to protect armour and insulation.
  • Ensure glands and accessories are compatible with SWA construction.
  • Keep cable ends sealed before installation to prevent moisture ingress.
  • Follow local electrical codes and fire safety regulations.

 

FAQ

Q1: Is this cable suitable for fire alarm systems?

A: Yes. It is widely used in fire alarm systems, emergency lighting, smoke control systems, and critical power circuits requiring

continuous operation during a fire.


Q2: Can the cable be installed underground?

A: Yes. The galvanized steel wire armour provides mechanical protection, making it suitable for underground and outdoor

installations when properly installed.


Q3: Why choose LSZH sheath material?

A: LSZH materials emit very little smoke and no halogen gases during combustion, improving visibility and reducing damage to

people and electronic equipment.


Q4: Can customized sizes and lengths be supplied?

A: Yes. CHATNOW provides customized conductor sizes, core counts, sheath colors, printing, and packing lengths according to

project requirements.


Q5: What is the regular packing length?

A: The standard packing is 500 meters per wooden drum, with custom lengths available upon request.

 

CHATNOW TECHNOLOGY

Reliable Fire Protection for Critical Power Circuits

  • BS 6387 CWZ Certified Design
  • Low Smoke Zero Halogen Construction
  • Steel Wire Armoured Protection
  • Stable Electrical Performance
  • OEM & Customized Solutions Available
  • Suitable for Emergency and Life Safety Applications

 

ABOUT COMPANY

07
08
09
9
8
7
6
5
4
1

 

CERTIFICATIONS

CERTIFICATIONS 1
CERTIFICATIONS 1
CERTIFICATIONS 2
CERTIFICATIONS 2
CERTIFICATIONS 3
CERTIFICATIONS 4
E540176-Fire Resistant Cable COC
 

 

MANUFACTURING PROCESS

MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
MANUFACTURING PROCESS
 

 

QUALITY INSPECTION

12
13
14
15
16
17
18
 

 

 

 

 

 

 

 

 

 

 

Hot Tags: fire-resistant cable bs 6387 cwz 3c×6mm2, China fire-resistant cable bs 6387 cwz 3c×6mm2 manufacturers, suppliers, factory, Fire resistant Cable PH120 2 1 5mm Solid Shielded, Fire resistant Cable PH120 2 2 5mm Solid Shielded, Fire resistant Cable PH120 3 2 5mm Solid Shielded

CONSTRUCTION

Conductor Material

Stranded bare copper wire

Conductor Surface / Structure

19×0.63mm

Refractory Deposition Material

Double Mica Tape

Core Insulation Material

XLPE

Screen1 Material

Single Al/pet

Screen2 Material

LSZH Tape

Inner Jacket

LSZH

Armoured

Steel Wire Armour

Material Outer Sheath

Flame retardant LSZH

 

CHARACTERISTICS

Cable performance(at 20℃)

Data of product

Inner Conductor DC Resistance

≤3.08Ω/km

Dielectric strength 3500V/5min No breakdown

 

SPECIFIATION FOR APPROVAL

Working voltage 0.6/1kV
Temperature range -20~+90℃
Flame Retardant IEC 60332-1-2
Circuit Integrity BS6387 CWZ
General requirements RoHS 2.0

Operating temperature